Premium 40.5KV 1600A Dry Wall Bushings with Current Transformer for Enhanced Substation Performance

Product Details
Customization: Available
Application: High-voltage
Material: Porcelain / Composite Polymer
Still deciding? Get samples of US$ 350/Piece
Request Sample
Manufacturer/Factory, Trading Company, Group Corporation
Diamond Member Since 2018

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
5000000 RMB
Plant Area
>2000 square meters
  • Premium 40.5KV 1600A Dry Wall Bushings with Current Transformer for Enhanced Substation Performance
  • Premium 40.5KV 1600A Dry Wall Bushings with Current Transformer for Enhanced Substation Performance
  • Premium 40.5KV 1600A Dry Wall Bushings with Current Transformer for Enhanced Substation Performance
  • Premium 40.5KV 1600A Dry Wall Bushings with Current Transformer for Enhanced Substation Performance
  • Premium 40.5KV 1600A Dry Wall Bushings with Current Transformer for Enhanced Substation Performance
  • Premium 40.5KV 1600A Dry Wall Bushings with Current Transformer for Enhanced Substation Performance
Find Similar Products

Basic Info.

Model NO.
Wall Bushing
Structure
Wall Bushing
Type
A Type Insulator
Usage
High Voltage Power Transmission, Insulation, Electrical Installation
Connection Method
Bolting Type
Size of Bearing Capacity
5000N
Certification
CCC, CE, ISO9001
Color
brown / Gray
Brand
NJREC
Voltage Range
1kV-1200kV
Current Range
1A-10000A
Internal Insulation
Copper / Aluminum
External Insulation
Porcelain / Silicone Rubber
Standard
IEC 60137, GB/T4109
Delivery
35 Days
Transport Package
Wooden
Trademark
NJREC
Origin
Jiangsu, China
Production Capacity
2000pieces/Year

Product Description

Product Description
  1.  FCRG dry type composite capacitive type wall bushings is an independently developed and innovated product in China; The main insulation inside the casing is divided into two types: composite film capacitor main insulation and rubber immersed fiber capacitor main insulation.The external insulation is divided into high-temperature vulcanized silicone rubber composite jacket and porcelain jacket, which can meet the needs of different users;
  2.   Based on standards:lEC60137.GB/T4109;
  3.   Product features: non oil filled, non air filled, fireproof, explosion-proof, environmentally friendly, maintenance free, and strong pollution resistance; The composite film capacitive sleeve has a relatively lighter weight, while the adhesive impregnated fiber capacitive sleeve has a relatively stronger mechanical strength;
  4.   Main technical parameters:
  4.1 Environmentaltemperature:-40~+55°C
  4.2 Rated voltage:12kV~363kV
  4.3 Rated current: 10A~8000A

  Nanjing Rainbow Electric Co., Ltd Condenser bushings products are classified as Wall Bushing, Transformer Bushing, GIS Lead-out Bushing, Oil/Oil bushing that connects transformer and oil-filled equipment, and Oil/SF6 bushing that connects transformer and GIS. According to the capacitive main insulation, products are classified as Oil Impregnated Paper (OIP) Capacitor Bushing, Resin Impregnated Paper(RIP) Bushing, Glassfiber Reinforced Plastic (GFRP) Dry-type Bushing, and Vacuum Epoxy Resin Impregnated Fiberglass (RIP) Capacitor Bushing.

Standard IEC 60137-2017
Highest voltage for equipment kv 72.5 100 123 145 170 245 300 362
Rated frequency Hz 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60
Dry power frequency withstand voltage 1 minute kv 155 205 255 305 355 505 505 560
Lightning impulse (BIL) kv 325 450 550 650 750 1050 1050 1175
Switching impulse (SIL) kv - - - - - 850 850 950
Maximum Rated Current A 2500 2500 2500 2500 2500 2500 2500 2500
Temperature range ºC Down to -60ºC up to +55ºC available on request

Premium 40.5KV 1600A Dry Wall Bushings with Current Transformer for Enhanced Substation PerformancePremium 40.5KV 1600A Dry Wall Bushings with Current Transformer for Enhanced Substation PerformancePremium 40.5KV 1600A Dry Wall Bushings with Current Transformer for Enhanced Substation PerformancePremium 40.5KV 1600A Dry Wall Bushings with Current Transformer for Enhanced Substation PerformancePremium 40.5KV 1600A Dry Wall Bushings with Current Transformer for Enhanced Substation PerformancePremium 40.5KV 1600A Dry Wall Bushings with Current Transformer for Enhanced Substation PerformancePremium 40.5KV 1600A Dry Wall Bushings with Current Transformer for Enhanced Substation PerformancePremium 40.5KV 1600A Dry Wall Bushings with Current Transformer for Enhanced Substation PerformancePremium 40.5KV 1600A Dry Wall Bushings with Current Transformer for Enhanced Substation PerformancePremium 40.5KV 1600A Dry Wall Bushings with Current Transformer for Enhanced Substation PerformancePremium 40.5KV 1600A Dry Wall Bushings with Current Transformer for Enhanced Substation PerformancePremium 40.5KV 1600A Dry Wall Bushings with Current Transformer for Enhanced Substation PerformancePremium 40.5KV 1600A Dry Wall Bushings with Current Transformer for Enhanced Substation PerformancePremium 40.5KV 1600A Dry Wall Bushings with Current Transformer for Enhanced Substation Performance
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier